Lithium Battery Basics: Cell, Module and Battery Pack

A lithium battery is built in three levels: the cell, the module and the pack. This article explains how they differ, how series and parallel configurations set voltage and capacity, what a BMS does, and what Ah, Wh and C-rate mean.
Many people call any stored power source a "battery". In energy storage, however, there are three distinct levels: cell, module and pack. Telling them apart matters, because their price, specifications and handling are not the same.
We keep the language as simple as possible. This is the first article in our series on battery assembly.
Cell: the smallest unit
A cell is the smallest and most basic battery unit. A cell has two terminals, positive and negative, and one nominal voltage.
The voltage of one cell is not high. Lithium-ion cells typically have a nominal voltage of about 3.6 to 3.7 volts, while lithium iron phosphate (LFP) cells are about 3.2 volts. For this reason, a single cell is almost never enough for real applications such as an electric motor or home energy storage.
Cells come in several physical formats:
- Cylindrical: a tube shape like an ordinary battery, but larger. Common sizes include 18650 and 21700.
- Prismatic: a box shape with a rigid case. This format is easy to pack tightly, and its terminals are bolt-type, so the connections are strong.
- Pouch: a soft sheet wrapped in aluminum laminate. It is light, but needs an external frame to hold it.
Cimahi Battery Industry manufactures prismatic cells. This format is widely chosen for energy storage because the cells pack tightly and the terminal connections are solid.
Module: several cells combined
A module is a group of cells that have been arranged, connected and fitted with a frame. A module cannot be used on its own, because it has no protection or control yet. Think of a module as a "building block" that is later assembled into a pack.
In small packs, the module stage is sometimes skipped. The cells are assembled directly into one pack. The technical term is cell-to-pack.
Pack: a battery ready for use
A battery pack is the final form that can actually be installed in a device. It contains:
1. Cells or modules, which store the energy.
2. Busbars and cables, which connect the cells.
3. BMS (Battery Management System), the protective brain of the pack. Its functions are explained below.
4. Casing, which protects against impact, water and dust.
5. Additional protection, such as a fuse or breaker.
6. Output terminals, where the load and charger cables are connected.
Series and parallel: how voltage and capacity are set
This is the most frequently asked part. Cells can be arranged in two ways, and each gives a different result.
Series connection (written S) adds voltage. Capacity stays the same. Example: 4 LFP cells of 3.2 volts in series give 12.8 volts. This is why lithium batteries that replace 12-volt lead-acid batteries usually have a 4S configuration.
Parallel connection (written P) adds capacity. Voltage stays the same. Example: 2 cells of 100 Ah in parallel give 200 Ah, and the voltage does not change.
For this reason, pack configurations are often written like 16S1P: sixteen cells in series, one parallel string. With LFP cells, the result is about 51.2 volts, usually called the 48-volt class.
Key terms
- Volt (V): Voltage. Increased by adding cells in series.
- Ampere-hour (Ah): Charge capacity. Increased by adding cells in parallel.
- Watt-hour (Wh): Amount of energy. Calculated as voltage multiplied by capacity. Example: 51.2 V x 100 Ah = 5,120 Wh, or about 5.1 kWh.
- C-rate: A measure of charge or discharge speed. 1C is the current that discharges the full capacity in one hour. For a 100 Ah pack, 1C equals 100 amperes.
- SoC: State of Charge, the remaining charge in percent.
- Cycle: One full charge and discharge. The number of cycles a pack can reach depends heavily on pack design, depth of discharge and operating temperature.
Note that Wh is the fairest figure for comparing two packs. Two packs can both be "100 Ah" yet store very different amounts of energy if their voltages are not the same.
BMS: protection you cannot skip
A BMS is an electronic board that monitors the pack from the inside. Its tasks:
- Monitoring the voltage of every cell, not only the total voltage. This is the most important part.
- Monitoring temperature through sensors placed near the cells.
- Cutting off current in case of overcharge, over-discharge, overcurrent or short circuit.
- Balancing the cells, that is, equalizing the voltages of cells that gradually drift apart.
Why monitor each cell? Because a pack is only as strong as its weakest cell. When the pack is charged, the cell with the smallest capacity becomes full first. If nothing cuts off the charge, that cell keeps charging and can be damaged, even though the total pack voltage still looks normal. The opposite happens during discharge.
This is why cells must be sorted and grouped before assembly. The next article covers this.
Off-the-shelf or custom pack?
An off-the-shelf (standard) pack suits common needs, for example replacing a 12-volt lead-acid battery. A custom pack is needed when:
- space is limited or has an unusual shape, so a standard pack does not fit;
- the voltage and capacity are specific, to match an existing inverter or controller;
- data communication is needed with other devices;
- it will be used in a particular environment, such as outdoors or at high temperature.
Cimahi Battery Industry builds custom battery packs in addition to manufacturing prismatic cells, so the configuration, casing and BMS selection can be matched to your requirements.
Next
The next article covers the battery pack assembly steps, from inspecting newly arrived cells to final testing before the pack is shipped.
To discuss your cell or battery pack requirements, contact the Cimahi Battery Industry team via WhatsApp +62 822 6090 4770 or email cimahibattery@gmail.com.
Need cells or packs for your product? See our profile as a lithium battery manufacturer in Indonesia and the LiFePO4 prismatic cells catalogue.
Need Battery Pack Engineering or Material Testing?
Discuss industrial-grade custom lithium battery assembly or laboratory material testing directly with CBI engineers.
Related Articles & Insights
View All Articles ⟶12V Lithium Battery as a Lead-Acid Replacement
12-volt lithium batteries are increasingly used in place of lead-acid batteries (aki) for emergency lights, UPS units, small solar setups, boats and camping gear.
Lithium Battery BMS: Functions, Types and Selection
Every safe lithium battery pack has a BMS, short for Battery Management System.